001A3A (Head Hot Error)
Error contents
- Head internal failure (abnormal heat generation)
- The Head IC detected an abnormal temperature.
Suspected cause
- Head internal IC failure
- The head operated without ink supplied, and temperature rose.
- The ink supply side could have failed.
Parts/Components to be checked
- Head FFC Assy
- Print Head
- CH83 DRV-H Board
- CH83 Main-B Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check that print quality is normal. If multiple nozzles have been clogged, perform cleaning. Does the product recover from the error? | Cleaning | End | Go to step 2 |
2 | Check the Head FFC connection state
Does the product recover from the error? | Head FFC Assy | End | Go to step 3 |
3 | Replace the Print Head Does the product recover from the error? | Print Head | End | Go to step 4 |
4 | Replace the CH83 DRV-H Board Does the product recover from the error? | CH83 DRV-H Board | End | Go to step 5 |
5 | Replace the CH83 Main-B Circuit Board Does the product recover from the error? | CH83 Main-B Circuit Board | End | Escalate to person in charge |