00124A (Sub PF Driven Roller Motor Overload Error)
Error contents
- Overcurrent to the Sub PF Driven Roller Motor was detected.
- The Sub PF Driven Roller Motor rotation speed is not attained or is not detected correctly.
Suspected cause
- Abnormal load
- Sub PF Driven Roller Motor Encoder cable abnormality (connection, broken)
- Sub PF Driven Roller Motor cable abnormality (connection, broken)
- Sub PF Driven Roller Motor Encoder failure
- Sub PF Driven Roller Motor failure
- CH83 Main-B Circuit Board failure
Parts/Components to be checked
- Sub PF Encoder
- Sub PF Driven Roller Motor
- CH83 Main-B Circuit Board
- Sub PF Belt
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check for obstacles in the Sub PF operation range
Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the Sub PF Encoder cable connection.
Does the product recover from the error? | Sub PF Encoder | End | Go to step 3 |
3 | Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.
Does the product recover from the error? | End | Go to step 4 | |
4 | Replace the Sub PF Encoder. Does the product recover from the error? | Sub PF Encoder | End | Go to step 5 |
5 | Check the Sub PF Belt state.
Does the product recover from the error? | End | Go to step 6 | |
6 | Replace the Sub PF Driven Roller Motor. Does the product recover from the error? | Sub PF Driven Roller Motor | End | Go to step 7 |
7 | Replace the CH83 Main-B Circuit Board. Does the product recover from the error? | CH83 Main-B Circuit Board | End | Escalate to person in charge |