00130D (ASF Motor Driving Time-Out Error)
Error contents
- Abnormally-long driving duration of the ASF Motor was detected.
Suspected cause
- Firmware becomes out of control
- Abnormal load
Parts/Components to be checked
- Printer Main Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Firmware Update Does the product recover from the error? | Firmware Install | End | Go to step 2 |
2 | Replace the Printer Main Circuit Board. Does the product recover from the error? | Printer Main Circuit Board | End | Escalate to person in charge |