00151A (APG Motor Overload Error)
Error contents
- There is an abnormality in the APG Motor connection.
- Overcurrent to the APG Motor was detected.
- APG Encoder cable broken
Suspected cause
- Abnormal load
- APG Motor Encoder cable abnormality (connection, broken)
- APG Motor cable abnormality (connection, broken)
- APG Motor Encoder failure
- APG Motor failure
Parts/Components to be checked
- APG Unit
- Printer Main Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the obstacle in the APG operation range
Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.
Does the product recover from the error? | End | Go to step 3 | |
3 | Check if there is any foreign object in the driving section of the APG Unit. Does the product recover from the error? | APG Unit | End | Go to step 4 |
4 | Replace the APG Unit. Does the product recover from the error? | APG Unit | End | Go to step 5 |
5 | Replace the Printer Main Circuit Board. Does the product recover from the error? | Printer Main Circuit Board | End | Escalate to person in charge |