00151A (APG Motor Overload Error)

Error contents
  • There is an abnormality in the APG Motor connection.
  • Overcurrent to the APG Motor was detected.
  • APG Encoder cable broken
Suspected cause
  • Abnormal load
  • APG Motor Encoder cable abnormality (connection, broken)
  • APG Motor cable abnormality (connection, broken)
  • APG Motor Encoder failure
  • APG Motor failure
Parts/Components to be checked
  1. APG Unit
  2. Printer Main Circuit Board
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Check the obstacle in the APG operation range

  • Check if any obstacle is blocking the APG movement. If so, remove the obstacle.

Does the product recover from the error?

---EndGo to step 2
2

Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.

  • APG Motor Encoder (No.25) to Printer Main Circuit Board (CN829)
  • APG Motor (No.2) to Printer Main Circuit Board (CN829)

Does the product recover from the error?

EndGo to step 3
3

Check if there is any foreign object in the driving section of the APG Unit.

Does the product recover from the error?

APG UnitEndGo to step 4
4

Replace the APG Unit.

Does the product recover from the error?

APG UnitEndGo to step 5
5

Replace the Printer Main Circuit Board.

Does the product recover from the error?

Printer Main Circuit BoardEndEscalate to person in charge