001418 (Pump Cap Unit Overload Error)
Error contents
- The cycle of voltage to the Pump Motor is unstable and the number of overcurrent detections reached the specified value.
Suspected cause
- Pump Motor or Pump Motor Encoder cable abnormality (connection, broken)
- Abnormal load
- Pump Motor Encoder failure
- Pump Motor failure
- Pump Cap Unit cable abnormality (connection, broken)
Parts/Components to be checked
- Pump Cap unit
- Printer Main Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.
Does the product recover from the error? | End | Go to step 2 | |
2 | Check the Pump Cap Unit operation state.
Does the product recover from the error? | Pump Cap unit | End | Go to step 3 |
3 | Replace the Printer Main Circuit Board. Does the product recover from the error? | Printer Main Circuit Board | End | Escalate to person in charge |