00154A (Cutter Motor Overload Error)

Error contents
  • Overcurrent is detected more than predetermined limit since the Cutter Motor did not operate properly because of some kind of load.
Suspected cause
  • Cutter Motor Encoder cable abnormality (connection, broken)
  • Cutter Motor cable abnormality (connection, broken)
  • Abnormal load
  • Cutter Motor Encoder failure
  • Cutter Motor failure
Parts/Components to be checked
  1. Cutter Motor Unit
  2. Cutter Rail Unit
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Check the obstacle in the cutter moving range.

  • Check if any obstacle is blocking the cutter movement. If so, remove the obstacle.

Does the product recover from the error?

---EndGo to step 2
2

Check the cable connection of the Cutter Motor Unit

  • Check the connection status of the Cutter Motor Unit and, if abnormal, reconnect.

Does the product recover from the error?

Cutter Motor UnitEndGo to step 3
3

Replace the Cutter Motor Unit.

Does the product recover from the error?

Cutter Motor UnitEndGo to step 4
4

Replace the Cutter Rail Unit.

Does the product recover from the error?

Cutter Rail UnitEndEscalate to person in charge