00154A (Cutter Motor Overload Error)
Error contents
- Overcurrent is detected more than predetermined limit since the Cutter Motor did not operate properly because of some kind of load.
Suspected cause
- Cutter Motor Encoder cable abnormality (connection, broken)
- Cutter Motor cable abnormality (connection, broken)
- Abnormal load
- Cutter Motor Encoder failure
- Cutter Motor failure
Parts/Components to be checked
- Cutter Motor Unit
- Cutter Rail Unit
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the obstacle in the cutter moving range.
Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the cable connection of the Cutter Motor Unit
Does the product recover from the error? | Cutter Motor Unit | End | Go to step 3 |
3 | Replace the Cutter Motor Unit. Does the product recover from the error? | Cutter Motor Unit | End | Go to step 4 |
4 | Replace the Cutter Rail Unit. Does the product recover from the error? | Cutter Rail Unit | End | Escalate to person in charge |