001419 (Pump Cap Unit Oscillation Error)

Error contents
  • The number of oscillations exceeds the specified value.
  • The control terminal (Vre terminal) of the Pump Motor Driver was short-circuited.
Suspected cause
  • Printer Main Circuit Board failure
  • Pump Cap Unit failure
Parts/Components to be checked
  1. Printer Main Circuit Board
  2. Pump Cap unit
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Check the Printer Main Circuit Board state

  • Check if any foreign object is on the Printer Main Circuit Board. If a foreign object is found, remove it.

Does the product recover from the error?

Printer Main Circuit Board

EndGo to step 2
2

Replace the Printer Main Circuit Board.

Does the product recover from the error?

Printer Main Circuit Board

EndGo to step 3
3

Replace the Pump Cap Unit

Does the product recover from the error?

Pump Cap unitEndEscalate to person in charge