001A38 (Transistor Environmental Temperature Error)
Error contents
- The temperature rose and reached the specified value due to an abnormality in the Transistor Circuit on the CH83 DRV-H Board.
- The thermistor on the CH83 DRV-H Board erroneously detected and stopped.
Suspected cause
- Abnormality in the Transistor Circuit on the CH83 DRV-H Board.
- The thermistor on the CH83 DRV-H Board erroneously detected.
- Cable connecting the main circuit board to the CH83 DRV-H Board is broken.
Parts/Components to be checked
- CH83 DRV-H Board Cooling Fan
- CH83 DRV-H Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the suction inlet of the fan for clogging with dirt or foreign objects, and remove. Does the product recover from the error? | CH83 DRV-H Board Cooling Fan | End | Go to step 2 |
2 | Check for foreign objects on the CH83 DRV-H Board. If a foreign object is found, remove it. Does the product recover from the error? | CH83 DRV-H Board | End | Go to step 3 |
3 | Check if the fan is operating (cable connection check/fan/board/cable broken) Does the product recover from the error? | End | Go to step 4 | |
4 | Replace the CH83 DRV-H Board Does the product recover from the error? | CH83 DRV-H Board | End | Go to step 5 |
5 | Replace the CH83 DRV-H Board Cooling Fan. Does the product recover from the error? | CH83 DRV-H Board Cooling Fan | End | Escalate to person in charge |