FB PID lock detection (error code: 100067)
Occurrence condition
When rotated in the opposite direction to rotation direction (There was a sudden load error, and the motor rotated in the opposite direction in reaction to it)
State in which load of the SCN motor exceeds expected load, and motor does not rotate at all
State in which load of the SCN Motor exceeds expected load
Suspected cause
FFC disconnection insertion failure in ADF/SCN
Main Board failure.
SCN Encoder failure
SCN Scale is dirty or damaged.
SCN Motor failure
Related parts
- ADF/SCN Unit
- Main Board Assy
Troubleshooting
Procedure | Check and measure | Yes | No |
---|---|---|---|
1 | Visually check the FFCs of the ADF/SCN Unit.
| Go to step 2 |
|
2 | Replace the ADF/SCN Unit.
| Go to step 3 | End |
3 | Replace the Main board Assy.
| Contact the EPSON Service Department. | End |