LFT3 PID driving time error (error code: 000200)

Occurrence condition
  • The drive time of the Optional LIFT Motor has exceeded a fixed value.

Suspected cause
  • Optional Cassette ASF Motor cable failure

  • Optional Paper Cassette Main Board Assy failure

Related parts
  • Replace the Optional Paper Cassette Main Board Assy.
  • Replace the Optional Cassette Unit.
Troubleshooting
ProcedureCheck and measureYesNo
1

Optional Cassette ASF Motor cable failure
Is the optional cassette ASF motor cable (CN13) connected properly?

Go to step 2
  • Correctly insert the optional cassette ASF motor cable (CN13).
  • Replace the Optional Cassette Unit in the case of damage of the motor cable. (Go to step 3)
2

Replace the Optional Paper Cassette Main Board Assy.
Does the error occur after replacing the Optional Paper Cassette Main Board Assy?

Go to step 3

End
3Replace the Optional Cassette Unit.
Does the error occur after replacing the Optional Paper Cassette Unit?
Contact the EPSON Service Department.End