FB PID driving time (error code: 100070)
Occurrence condition
- The driving time of the SCN Motor exceeded the set time.
Suspected cause
FW failure
FFC disconnection in ADF/SCN
Main Board failure.
Related parts
- ADF/SCN Unit
- Main Board Assy
Troubleshooting
Procedure | Check and measure | Yes | No |
---|---|---|---|
1 | Check for the firmware.
| Go to step 2 |
|
2 | Visually check the FFCs of the ADF/SCN Unit.
| Go to step 3 |
|
3 | Replace the ADF/SCN Unit.
| Go to step 4 | End |
4 | Replace the Main board Assy.
| Contact the EPSON Service Department. | End |