IS load position reverse error (error code: 000113)
Occurrence condition
The IS Motor drive has been reversed.
Suspected cause
Contamination of IS Scale
Related parts
- Inksystem Assy
Troubleshooting
Procedure | Check and measure | Yes | No |
---|---|---|---|
1 | Visually check for the IS Scale.
| Go to step 2 |
|
2 | Replace the Inksystem Assy.
| Contact the EPSON Service Department. | End |