How to change settings in FAX Maintenance Mode 1 (select setting item)

Example of setting change

"Transmission signal level (TX SIGNAL LEVEL)" Change the initial value "-10dBm" to "-15dBm".

1

Press “Select Key: [0-9]”,  and input "120"
Press the [#] key to confirm the entry.

FAX Parameter Setting
[120]
120 TX SIGNAL LEVEL
121 RX SIGNAL DET LEVEL
122 TX EQUALIZER
123 RX EQUALIZE
124 ---
125 ---
126 ---
127 ---
128 ---
129 ---


Select: [0-9] or [*] / Enter: [♯]

2

The “Setting value input screen” (during input) is displayed as shown on the left.

The current value is displayed at the top of the screen, and the range of values that can be entered is displayed.

Enter the setting value using the numeric keypad, confirm that the setting value is displayed in the setting value entry field, and press the [#] key to confirm the entry.

FAX Parameter Setting
120 TX SIGNAL LEVEL
Current :   10 [-dBm]

Input New Value

[ 15] ( 0 - 15)


Select: [0-9] or [*] / Enter: [♯]

3

The “Set value input screen” (after setting) is displayed as shown in the figure.

The set value is displayed in "Current" at the top of the screen.

To set parameters continuously, press Back to Parameter List [L] to move to the parameter selection screen.
When finished, press the power switch to turn off the power.

X Parameter Setting
120 TX SIGNAL LEVEL
Current : 15 [-dBm]


Parameter is set


Back to Parameter List: [♯]