How to change settings in FAX Maintenance Mode 1 (select setting item)
Example of setting change
"Transmission signal level (TX SIGNAL LEVEL)" Change the initial value "-10dBm" to "-15dBm".
1 | Press “Select Key: [0-9]”, and input "120" | FAX Parameter Setting Select: [0-9] or [*] / Enter: [♯] |
2 | The “Setting value input screen” (during input) is displayed as shown on the left. | FAX Parameter Setting
|
3 | The “Set value input screen” (after setting) is displayed as shown in the figure. The set value is displayed in "Current" at the top of the screen. To set parameters continuously, press Back to Parameter List [L] to move to the parameter selection screen. | X Parameter Setting Parameter is set Back to Parameter List: [♯] |