CR PID excess speed error 2 (error code: 000027)
Occurrence condition
State in which load of CR Motor exceeds expected load
When rotated in the opposite direction to rotation direction (There was a sudden load error, and the motor rotated in the opposite direction in reaction to it)
Suspected cause
Disconnection or contact failure of the CR Encoder FFC
Collision with jammed paper
Collision with a foreign object
CR Lock Lever failure (Inksystem Unit failure)
High sliding load (oil cutoff, paper dust, mist)
CR Scale is dirty or damaged.
CR Encoder failure
CR Motor failure
Main Board failure.
Related parts
- Inksystem Assy
- CR Scale
- CR Encoder FFC (Head FFC)
- CR Encoder
- CR Motor
- Main Board Assy
Troubleshooting
Procedure | Check and measure | Yes | No |
---|---|---|---|
1 | Visually check the CR scanning section
| Go to step 2 |
|
2 | Check the CR Lock Lever operation
| Go to step 3 |
|
3 | Check the status of the CR Guide Frame
| Go to step 4 |
|
4 | Check the CR Scale state.
| Go to step 5 |
|
5 | Check the status of the CR Encoder FFC
| Go to step 6 |
|
6 | Check the CR Encoder state
| Go to step 7 |
|
7 | Visually check the CR Motor cable.
| Go to step 8 |
|
8 | Replace the Main board Assy.
| Replace the Printer Mechanism. | End |