Extension Spring 27.7 (WF-M5399 Series)
- Remove the Rear Unit (A) in the direction of the arrow while pressing the buttons inward.
- Open the ASF Cover (A) and remove the two screws securing the Rear Housing Assy (B).
: C.B.P-TITE-SCREW-3x10-F.ZB-3C
- Remove the four screws securing the Rear Housing (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
Remove the Rear Housing (A) downward.
Assembly / 組み立て
Attach the two dowels of the Rear Housing (A) to the positioning holes on the Housing Left (B) and the Housing Right (C).
Remove the Rear Upper Cover Assy (A) in the direction of the arrow.
Assembly / 組み立て
Insert the four tabs of the Rear Upper Cover Assy (A) to the positioning holes of the Housing ASF (B).
- Remove the two screws securing the Housing ASF (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
- Open the Printer Cover (A) and remove the four screws, and then remove the Housing ASF (B).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
- Disengage the hook, and remove the Maintenance Box Cover (A).
- Remove the three screws securing the Housing Right (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
- Remove the two screws securing the Housing Right (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
- Lift the Housing Right (A) upward to release the two hooks on the front side of the Housing Right (A).
Remove the dowels to the rear, and lift up the Housing Right (A) to remove it.
Assembly / 組み立て
Insert the four tabs of the Housing Right (A) to the positioning holes of the RIPS Unit (B).
- Remove the three screws securing the Housing Left (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
- Remove the two screws securing the Housing Left (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
Lift the Housing Left (A) upward to release the two hooks each on the front side and rear side of the Housing Left (A), and then remove the Housing Left (A).
Assembly / 組み立て
Insert the four tabs of the Housing Left (A) to the positioning holes of the RIPS Unit (B).
- Remove the Printer Cover (A) upward.
- Remove the seven screws and remove the Housing Top (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
- Remove the two screws securing the Cable Guide (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
Check Point / チェックポイント
When removing the screws, if the screwdriver interferes with the ADF/SCN Unit, use a stubby screwdriver.
- Peel off the CRCM FFC (B) from the CRCM FFC Sheet (A).
- Peel off the double-sided tape at two locations and then remove the CRCM FFC Sheet (A).
- Disconnect the cables (B) from the connector (CN20, CN51, CN56) of the Relay Board (A).
- Remove the acetate tape (A), and release the cable (B) from the two guides.
- Disconnect the two cables (B) from the connectors (CN74, CN80) of the Main Board (A).
- Remove the two screws, and release the ground wire (A) from the slit to remove it.
: C.B.S-TITE-SCREW-3x6-F.ZN-3C
Assembly / 組み立て
Attach the ground wire with the terminal (A) oriented as shown below.
- Move the Cable Guide as shown below.
- Remove the two screws, then remove the PS Ground Plate (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
: C.B.S-TITE-SCREW-3x6-F.ZN-3C
Check Point / チェックポイント
A ground wire (B) is connected to the PS Ground Plate (A) depending on the region of sale.
If the ground wire (B) is connected, remove the wire (B) by removing the screw.
: C.B.(O)SCREW,4X5,F/ZN-3C
Assembly / 組み立て
Assemble ensuring that screw types are correct.
- Disconnect the FFCs (A) and cables (B) from the connectors (CN2, CN9, CN51, CN55, CN609) on the Main Board.
Disconnect the FFCs (A) and cable (B) from the connectors (CN3, CN67, CN66, CN68, CN41, CN8) on the Main Board.
Check Point / チェックポイント
Release the connector (CN41) on the Main Board by lowering the connector lock in the direction of the arrow.
- Disconnect the cable (A) from the connector (CN802) on the Main Board.
- Disconnect the FFCs (A) and cables (B) from the connectors (CN50, CN52, CN72, CN73, CN75, CN77) on the Main Board.
- Remove the two pieces of double-sided tape for the FAX FFC (B) from the MB Shield Plate Upper (A), and remove the ferrite core (C) from the FAX FFC (B).
- Release the PE Sensor Cable (B) from the clamp (A).
- Peel off the double-sided tape of the Relay FFC (B) from the MB Shield Plate Upper (A).
- Release the CR motor cable (B) from two clamps (A).
- Remove the five screws securing the Main Board Assy (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
: C.B.S-TITE.P4.SCREW-3X8-F.ZN-3
- Remove the two screws securing the Main Board Assy (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
Caution / 注意
In the next step, be careful not to damage the PF Scale.
Disengage the hole of the Main Board Assy from the hook of the CR Guide Frame, then remove the Main Board Assy upward.
Assembly / 組み立て
Affix the FFC (B) to connect to the Main Board Assy (A) connector (CN52) using double-sided tape at the positions in the figure below.
- Release the FFC (A) from the three hooks.
Rotate the gear (B) of the Ink System Unit (A) in the direction of the arrow, and move the CR Unit (C) to the left side.
Caution / 注意
When rotating the gear of the Ink System Unit, take extra care not to damage or disconnect the FFC by touching it.
While holding the CR Driven Pulley Assy (A) by hand, remove the Extension Spring 27.7 (B) from the two hooks using long nose pliers.
Caution / 注意
In order to prevent the Extension Spring 27.7 from flying out, be sure to remove the spring while holding it with long nose pliers. Otherwise, the spring may fly out resulting in damaging your eyes or etc.