VBS over-voltage error (error code: 031008)
Occurrence condition
Occurs when an abnormal voltage is applied to the head drive circuit during printing.
Suspected cause
Head FFC oblique insertion and protective solution leakage
Print Head failure
Printhead drive circuit failure in main board
Related parts
- Printhead
- Main Board Assy
Troubleshooting
Procedure | Check and measure | Yes | No |
---|---|---|---|
1 | Visually check for solution leakage.
| Go to step 2 | Replace the Printhead and Head FFC Assy. |
2 | Visually check for the head FFC connection state.
| Go to step 3 | Properly connect the Head FFC. |
3 | Replace the Printhead.
| Go to step 4 | End |
4 | Replace the Main board Assy.
| Contact the EPSON Service Department. | End |